About These Installation Instructions- - - - - - - - - - - - - - - - - - - - - - 2Important Safety Instructions - - - - - - - - - - - - - - - - - -
Xantrex AC to DC Converter10 975-0301-01-01Installation CodesGoverning installation codes vary depending on the specific location and application of t
Installation Instructions975-0301-01-01 11• XADC converter faceplate and mounting hardware• Plastic bag containing two mounting tabs and related hardw
Xantrex AC to DC Converter12 975-0301-01-01Installing the XADC (stand-alone unit)Follow the procedures in the order given:1. “Preparing to Install”2.
Installation Instructions975-0301-01-01 13Preparing the Mounting Location for the XADCTo prepare the XADC mounting location:1. Place the XADC into the
Xantrex AC to DC Converter14 975-0301-01-01Connecting the AC InputWhen following the procedure, see Table 1 on page 24 for torque values.To connect th
Installation Instructions975-0301-01-01 15Mounting the XADCTo mount the XADC using the mounting plates:1. Align the XADC with the 4 previously marked
Xantrex AC to DC Converter16 975-0301-01-014. AC breaker positions 1 and 2 have been removed from the removable faceplate on the panel. Remove extra p
Installation Instructions975-0301-01-01 174. Take one of the side mounting flanges that you removed in step 2 above, and screw it to the bottom of the
Xantrex AC to DC Converter18 975-0301-01-01Preparing the Mounting Location for the XADC and PanelTo prepare the XADC and panel mounting location:1. Cu
Installation Instructions975-0301-01-01 193. Connect the incoming negative (-) black cable from each of the loads to the negative DC bus.4. Connect th
Xantrex AC to DC Converter2 975-0301-01-01About These Installation InstructionsPurposeThe purpose of these Installation Instructions is to provide exp
Xantrex AC to DC Converter20 975-0301-01-01Connecting the Panel to the XADC DC SideWhen following the procedure, see Table 2 on page 24 for wire lengt
Installation Instructions975-0301-01-01 21Connecting the Panel to the XADC AC SideWhen following the procedure, see Table 2 on page 24 for wire length
Xantrex AC to DC Converter22 975-0301-01-01Connecting the AC to the PanelSee “Connection Types for AC and DC” on page 18 if you are not familiar with
Installation Instructions975-0301-01-01 23AC LoadsTo install the AC loads:1. Route the AC load cables through the knockouts in the back of the panel.2
Xantrex AC to DC Converter24 975-0301-01-01Mounting the XADC and Panel RemotelyTo mount the XADC and panel remotely:1. Slide the panel into the mounti
Installation Instructions975-0301-01-01 25SpecificationsAll specifications are subject to change without notice. Additional specifications are availab
Xantrex AC to DC Converter26 975-0301-01-01TrademarksXantrex AC to DC Converter is a trademark of Xantrex International. Xantrex is a registered trade
Installation Instructions975-0301-01-01 3Important Safety Instructions1. Before installing and using the XADC, read all instructions and cautionary ma
Xantrex AC to DC Converter4 975-0301-01-01Explosive Gas PrecautionsPrecautions When Working With Batteries3. Make sure the area around the battery is
Installation Instructions975-0301-01-01 512. Use the XADC for charging a lead-acid battery only. Do not use the XADC to charge nickel-cadmium or dry-c
Xantrex AC to DC Converter6 975-0301-01-01InstallationMain ComponentsFigure 1 and Figure 2 show the main components of the XADC.Figure 1XADC External
Installation Instructions975-0301-01-01 7AC/DC Distribution PanelThe XADC may be pre-installed with an AC/DC Distribution Panel. The panel is availabl
Xantrex AC to DC Converter8 975-0301-01-01Figure 3AC/DC Distribution Panel ComponentsItem Description1 DC fuse/AC breaker access panel (swings open wi
Installation Instructions975-0301-01-01 9Figure 5AC/DC Distribution Panel and XADC Internal ComponentsItem Description1 Equipment Grounding Terminal b
Komentáře k této Příručce